General |
|
---|---|
Device type |
Carbon dioxide probe |
Range of application |
0…+50 °C / 0…95 %rh (non-condensing) |
IP protection |
IP40 |
Power supply / connection |
|
Power supply (VDD) |
3.3…5.5 VDC ±0 % |
Current consumption (16 s interval) |
20 mA (average). 260 mA (peak) |
Polarity protection |
Mechanical protection |
Battery life |
2.7 days with a 10 s or 60 s measurement interval |
CO2 measurement |
|
Sensor |
Infrared (NDIR) |
Parameter |
CO2 concentration (ppm/%) |
Measurement range |
0…2’000/5’000/10’000 ppm |
Resolution |
1 ppm |
Measurement accuracy (after minimum 3 weeks ABC) |
±50 ppm ±3 % of read value @ 0…2’000 ppm ±10 % of read value @ 2000…10,000 ppm |
Medium |
Air and non-aggressive gases |
Ambient pressure and temperature compensation |
Automatic (300…1100 hPa) |
Start time / measurement interval |
|
Startup time |
<300 s |
Measurement interval |
16 s |
Response time T63 |
130 s when descending 87 s when ascending |
Digital interface |
|
Type |
UART |
Protocol |
MODBUS RTU |
Factory default |
Baud rate 19200, tolerance 2 % Parity: none Data bits: 8 Stop bits: 1 Flow control: none |
Logic levels |
Logic 0: ≤0.4 V Logic 1: ≥2…2.5 V |
Maximum cable length |
5 m |
General specifications |
|
Housing material |
Polycarbonate (housing) |
Thumb screw material |
Stainless steel, DIN 1.4305 |
Weight |
55 g |
Conformity |
|
CE / EMC |
EMC Directive: 2014/30/EU
EN 61000-6-1:2007 EN 61000-6-2:2005 EN 61000-6-3:2007+A1:2011+AC:2012 EN 61000-6-4:2007+A1:2011 EN 61326-1: 2013
Performance criterion: www.rotronic.com |
Fire protection class |
Corresponds to UL94-V2 |
Soldering |
Lead free (RoHS Directive 2011/65/EU) |
FDA/GAMP directives |
Compatible |
Accepted environmental conditions |
|
Storage/transportation |
0…50 °C / 0…95 %rh, non-condensing |
Range of application (electronics) |
0…50 °C / 0…95 %rh, non-condensing |