New Features

ID

Description

RMS-1813A

Visual alarming, the measurement point box and status icon can be configured to:

Off.

Solid (measuring point box only as the status icon is always solid).

Flashing.

RMS-2386A

Device maintenance, all device maintenance can be logged within the audit trail:

Enable/disable service mode.

Definition of a service due date (reminder).

Service message that can be added to the audit trail:

oTemplate: Replace battery

oTemplate: Replace filter

oTemplate: Replace sensor

oTemplate: Firmware update

oFree text.

Service history view in the audit trial directly filtered for the device and service actions.

Service report including:

oTime and date of the report creation.

oOverview of all service actions on the device and corresponding measuring points.

oDevice specific services, including EVT number, date and description (including service and probe replace events).

oNext service due date.

oMeasuring point specfic services, including EVT number, date and description (including calibration, adjustment and probe replaced events).

RMS-2407A

Limit violations messages can be added to the events. A limit violation will only be created if the corresponding warning/alarm is configured with a delay.

RMS-3934A

Possibility to send a reminder E-Mail before an inhibition expires. This change also covers the requirements from RMS-678.

RMS-3964A

New pop up notifications above the menu bar, for reminders (yellow), warnings (orange), alarms (red) and errors (blue).

RMS-4744A

New device: RMS-LOG-W-T10-D, WiFi datalogger for NTC's with display.

RMS-4822A

New actions: it is now possible to send SMS's and make telephone calls via the actions menu. This change also covers the requirements from RMS-3254.

RMS-4877A

New device: RMS-LOG-W-D, WiFi datalogger for digital probes (HCD/TCD/PCD/CCD) with display.

RMS-5119A

New reset function for the WiFi loggers.

 

Improvements

ID

Description

RMS-665A

Group tree added to the events tab. This change also covers the requirements from RMS-926A and RMS-1122/2385/2479/3321.

RMS-2405A

Calibration due date automatically set (date MPT added to RMS + 1 year).

RMS-3430A

Security improvement: Assertion reuse.

RMS-3431A

Security improvement: No Request id validation.

RMS-3673A

The data validation in now done directly in a new MS SQL data table.

IMPORTANT: all users using the the HistoryView.sql must be sure to update the view with the new installation file.

RMS-3766A

SSO (SAML2.0): it is no longer necessary to have the IdP certificates used for response signature validation to be in the server root store. The certificates from the Metadata can be used to validate the response signature.

RMS-3933A

Under the events tab, the link to the layout where the DEV/MPT is visible is shown in each audit trail event.

RMS-4536A

Data export:

When a manual PDF is created with >10'000 events, an error message will be shown to the user.

When a manual CSV is created with >50'000 events, an error message will be shown to the user.

When an automated PDF is created with >10'000 events, multiple reports will be created and sent by E-Mail. Maximum number of reports: 50.

RMS-4756A

Repeat notifications can be setup per alarm level (reminder, warning, alarm and error) and per notification method (E-Mail, SMS, call and browser notification).

RMS-5123A

After deleting a user, device or measuring point, all data is deleted from the MS SQL database:

Disabled and deleted users are in the list of visible items in the event filter.

Deleted devices and measuring points cannot be filters in under events by name.

Filter possible by ID number within the "joint group" (the name is displayed as "unknown item").

 

Bug Fixes

ID

Description

RMS-3200A

Device repairing after deletion: device already exists error message.

RMS-3937A

Toggling virtual button too quickly creates Duplicate Key Exception errors.

RMS-4545A

Logfile entries: Message [DeviceConfigDto] was not delivered.

RMS-4581A

Unconfimed alarm counter not counting correctly.

RMS-4657A

Sorting MPT's in the archive view not working correctly.

RMS-4658A

Filtering firmware files in the document view not working correctly.

RMS-4683A

Registration of a new company with an empty name is possible.

RMS-4706A

Area mapping report fails if an uncertainty is set and the browser uses a language with a comma as decimal separator.

RMS-4750A

Pending readouts will not be recognized in the datagap analysis view, if multiple readouts has been combined.

RMS-4758A

Old open related events are documented in the events report.

RMS-4940A

High amount of E-Mail's sent after a data gap retry.

RMS-5020A

System settings signatures issue with special characters (öäüéèà).

RMS-5100A

"Enter password for changes" not working using SSO.

RMS-5138A

Events are not saved if the connection to the service manager is not available.

RMS-5374A

Validation error due to an incorrect SQL query.

RMS-5375A

Help E-mail send error.

RMS-5496A

The chart pop up is not visible after zooming in.

 