Update to V2.3.0 of the RMS Software

<< Click to Display Table of Contents >>

Navigation:  Software Overview > RMS Monitoring Software > Server Software Installation > RMS Software V2.3.0 >

Update to V2.3.0 of the RMS Software

 

Important:

As soon as the Rotronic Monitoring System >V2.0.0 has been uploaded, please update all RMS-GW devices with the latest firmware version: Update Firmware.

 

Please reach out to Rotronic for more details: rms@rotronic.ch.

 

Installing Multiple Instances.

 

Follow these guidelines for the installation of the V2.3.0

 

Prerequisites:

A previous version of RMS is already installed

The current version is hosted in IIS on the site “Default Web Site” and named “RMS” and “wService”

The new RMS Files are unzipped in the folder “C:\inetpub\wwwroot\RMS\21347”  

The “connection.config” file contains the correct information for the database connection

 

Step 1

Unzip the new version and copy it into a folder with the version number parallel to the currently installed version: "C://inetpub/wwwroot/rms/{version}".

 

clip0108

 

Step 2

Login to the SQL Server as ADMIN or SA user:

UpdateRmsFrom131To210_02

Step 3

Create a backup of the RMS database:

install software 2

Step 4

Update the database tables using the "Rotronic-RMS-Tables".Click on "open file" and double click on the folder to update.

 

clip0113l

 

The following data will be shown and click on execute. Please check before execute in which database you will run this script. The rms database should be shown in the left top field!

 

clip0119

 

Step 5

If the Software Version is same or higher as V1.3.X, double click on the "RMS_SQL_Indices" to upgrade and execute it. Please check with SQL Version is running on the server.

Please check before execute in which database you will run this script. The rms database should be shown in the left top field!

 

 

clip0114

 

 

 

 

clip0118

 

 

Step 6

Install the .Net Framework V4.7.2 or newer, double click on the file NDP472-KB4054531-WEB.exe:

UpdateRmsFrom131To210_06

 

When prompted click on continue to install the .NET framework or close if it is already installed:

UpdateRmsFrom131To210_07

Step 7

Check the existing settings can be found in "web.config" in folder \wService of the current RMS Installation. (DO NOT CHANGE ANYTHING IN THIS "web.config").

 

The current RMS installation can be seen under C:

clip0095

 

Edit, if required, the connection string (via Notepad) if the in "Connections.config" in folder C:\inetpub\wwwroot\RMS\20171\ServiceManager:

oData Source

oInitial Catalog

oUser ID

oPassword

 

UpdateRmsFrom131To210_08

Step 8

Test the connection to the database, by double clicking on the "TestDatabase.cmd" command:

UpdateRmsFrom131To210_09

 

 

If the following screen appears, return to step 5 and execute the "Rotronic-RMS-Tables":

 

clip0116

 

 

The following screen should be shown if the test is successful, you can forward to step 10:

 

UpdateRmsFrom131To210_10

Step 9

Important Note

If you update from <V1.3.3 , use the Update1xTo230.cmd

If you update from >V2.0.0 or higher, use the Update2xTo230.cmd

 

 

 

 

 

 

clip0115

 

Step

10

Open the "Update1ToV221.cmd" or "Update2toV221.cmd" file with notepad and check to ensure that the wPageName, wServiceName and ManagerInstance are all correct.

 

The correct details are listed below in yellow:

UpdateRmsFrom131To210_11

Step 11

Open the "RmsServiceManager.exe.config", in the ServiceManager file with notepad and check to ensure that the port = 8091:

UpdateRmsFrom131To210_12

 

Open the "NLog.config", in the ServiceManager file with notepad and check to ensure that the path is set to rms_files:

UpdateRmsFrom131To210_15

 

Open the "web.config", in the wPage file with notepad and check to ensure that the localhost:8091:

UpdateRmsFrom131To210_13

 

 

Open the "web.config", in the wService file with notepad and check to ensure that the localhost:8091:

UpdateRmsFrom131To210_14

 

Open the "NLog.config", in the wService file with notepad and check to ensure that the path is set to rms_files:

UpdateRmsFrom131To210_17

Step 12

Right click on the "Update1ToVxx.cmd" or "Update2toVxx.cmd" and run as administrator to run the update command and follow the steps in the script:

clip0100

 

Y

 

 

Y

 

clip0121

 

clip0122

 

clip0123

 

 

 

When prompted, enter "Y":

UpdateRmsFrom131To210_18

 

The following script will run:

UpdateRmsFrom131To210_19

Step 13

Recycle Application Pool ".NET V4.5" (in "IIS Manager" > "Application Pools" > "Recycle").

Step 14

Test to see if the website and the webservice are running:

Login to the website

 

Service test: ({ServerAddresse}/wService/wService3.DeviceService.svc/TestDatabase)

 

Install software 4

 

Step 15

Only if you want to add some other report Fonts, there is the instruction.

 

RMS V2.1 Add the Help Menu and Report Fonts.

Step 16

Update the Documentation path in the RMS software accordingly. The update created a new folder. The software update has created a new folder. We recommend either leaving the old folder as it is or integrating everything into the new one. If background images, layouts, etc. are used in the software, they must be copied from the old folder to the new one.

clip0124

 

clip0126

 

Step 17