<< Click to Display Table of Contents >> Navigation: Help > Troubleshooting > Previous Manuals > E-SM-RMS-WEB > System Startup > System Settings |
The menu "Tools" > "Setup" > "System" contains all settings that concern the overall system. They should be checked first of all and set accordingly for the application.
Visualization |
Description |
---|---|
Company logo |
It can be seen in RMS at all times at the top left oSupported formats: jpg, png oMaximum size: 512 kB oMaximum height: 76 pixels |
Title text |
It can be seen in RMS at all times at the top |
Title background |
Background color of the title line |
Local settings |
|
Culture |
Language region |
Time zone |
Select time zone |
Temperature |
Celsius / Fahrenheit |
Pressure |
Pressure unit: hPa / inch HG / PSI |
Differential pressure |
Differential pressure units: Pa / inH2O / mPSI, … |
Flow velocity |
m/s, km/h, ft/s, … |
Airflow |
m3/h, m3/s, m3/min, … |
CO2 |
PPM, % |
Particle |
p/m3, p/ft3 |
Humidity |
Display unit for humidity |
Gas constant |
Gas constant for MKT calculation (default: 0.0083144 kJ/K/mol) |
Activation Energy |
Activation Energy for MKT calculation (default: 83.144 kJ/mol) |
Security settings |
|
Allow deletion of measuring points |
oAllow: Measuring points (data set) are irretrievably deleted oDo not allow: Deleting of measuring points not allowed. Archiving however is possible if the option is licensed and the user has sufficient permission |
Allow deletion of users |
Allow/Not allow deleting users |
Enter password for changes |
The user must enter the password every time he wants to make a change. Concerns: setup, acknowledgment of alarms, adjustment, calibration |
Enter reason for changes |
The user must enter the reason every time he wants to make a change. Concerns: setup, acknowledgment of alarms, adjustment, calibration |
Do not reuse password |
How many times an old password may not be reused |
Change password to |
The password must be changed after the set number of days |
Min. length |
Minimum length of the password |
Password strength |
oThe password must contain upper and lower case letters oThe password must contain numbers or special characters |
Block user after |
The user is blocked after the set number of login errors |
Email server |
|
SMTP server |
SMTP server name |
User name |
SMTP user name |
Password |
SMTP password |
Sender name |
Email sender name |
Sender address |
Email sender address |
Encrypted connection |
Encrypted connection to email server |
Status email |
|
Send daily status email |
Daily status emails with information on the system1 (e.g. number of new measured values, number of devices, measuring points, users, etc.) |
Recipient |
Recipient of the status emails |
Web service |
|
Server address |
Web service URL (e.g. http://<server>/wService/wService3.DeviceService.svc/) |
Web page |
Web page URL (e.g. http://<server>/rms/ or http://<server>/. Not correct: http://<IP-Adress>/rms/) |
LDAP |
|
Server path |
LDAP server address. If credentials are required to access the LDAP server: Ask your system administrator for access permission for the identity of the IIS Application Pool. The user name in RMS need to be the same as in the operation system (e.g. Windows). |
Document path |
|
Document path2 |
Storage location for documents on the web server. This is the file folder location created during installation of RMS see Section 3.7 of E-IM-RMS-WEB. (e.g. C:\inetpub\wwwroot\RMS\rms_files) |
Repeat alarm |
|
Reminder |
Repetition interval of email and SMS |
Warning |
Repetition interval of email and SMS |
Alarm |
Repetition interval of email and SMS |
Error |
Repetition interval of email and SMS |
Telephone account (Not used, Worldwide or China) |
|
For option "China": |
Account settings are supplied by Rotronic when the service has been activated oApp ID oApp Key oTemplate (Test) oTemplate (Reminder) oTemplate (Warning) oTemplate (Alarm) oTemplate (Error) |
For option "Worldwide": |
|
Account ID |
Account ID3 |
Account token |
Account password4 |
SMS number |
Outgoing number of SMS notifications5 |
Call number |
Outgoing number of telephonic notifications6 |
Callback server |
URL for the telephone service7 |
Telephone alarm inhibition |
Alarm inhibition time after pressing the zero button in the case of telephonic alarms |
Telephone message selection |
Select which contents will be included in the telephone message. odevice/measure point ID odevice/measure point name odevice serial number odevice position omeasure point comment |
Import data |
|
Device |
Import devices (document provided with the validation package) |
User |
Import users (document provided with the validation package) |
1 Status emails are sent at midnight; the user must have the right "System notification".
2 The IIS web service must have write rights for the path, see the E-IM-RMS-WEB.
3 Is supplied by Rotronic when the service has been activated.
4 Is supplied by Rotronic when the service has been activated.
5 Is supplied by Rotronic when the service has been activated.
6 Is supplied by Rotronic when the service has been activated.
7 Is supplied by Rotronic when the service has been activated.