<< Click to Display Table of Contents >> Navigation: Humidity & Temperature Devices > Probes > HC1 > Technical specification |
HC1-X12 |
HC1-X19 |
|
|---|---|---|
Probe type |
Analog or Digital relative humidity and temperature |
|
Probe Diameter |
12mm |
19mm |
Measuring range |
-20 to 80 °C / 0 to 100 %rh |
|
Accuracy at 23 °C |
±2 %rh (10 to 90 %rh) / ±0.2 K |
1 Calibration Point: ±3 %rh (30 to 80 %rh) / ±0.3 K 2 Calibration Points: ±2 %rh (10 to 90 %rh) / ±0.2 K |
Long term stability |
<1 %rh / year |
|
Probe housing |
Molded polymer or stainless steel |
|
IP Protection rating |
IP65 |
|
Power supply |
14…30 VDC (0…5 V/ 0…10 V output) 5…30 VDC (0…1 V & mA output) |
|
Output signal |
0 to 1V, 0 to 5V, 0 to 10 V RS485 |
4 to 20 mA 0 to 1V, 0 to 5V, 0 to 10 V RS232, RS485 |
Response time rh sensor |
<10 sec typical (for 90% of the step change) |
|
Electrical connections |
4 pin M8 connector, 4 pin M12 connector |
M12 |