<< Click to Display Table of Contents >> Navigation: Software Overview > RMS Monitoring Software > Software Release Notes > V2.0.0.19353 |
ID |
Description |
RMS-2259 |
New software architecture. •The system is improved for larger amounts of devices and measuring points. •Stability improvement. |
Improvements
ID |
Description |
RMS-2533 |
Change gateway concept: •The average of the last 5 RSSI values is taken. •If one value is missing, the average RSSI value will be reduced by 10. •The gateway will be switched if the difference is >=15dB (or 10dBm if the RSSI <-90dBm). |
RMS-2532 |
Adapted the download commands: •The download commands will be sent over a period of 3 days. After 3 days a data gap will be created. •The download command will be sent at increasing intervals. The intervals will be doubled until a maximum of 2 hours (ex: 1, 2, 4, 8, 16, 32, 64, 120, 120, 120...). •Within 3 days, the around 40 download trials will happen. |
RMS-2534 |
The RMS-Monitor has been removed from the system. |
RMS-2586 |
The RMS software will work with the latest Google Chrome update (Javascript). |
ID |
Description |
RMS-2389 |
Typo: "AES Key Refresh" not "AES Key Refeseh". |
RMS-2383 |
Unit missing in PDF reports. |
RMS-2294 |
Property definitions cannot be overwritten. |
RMS-2293 |
Firmware update: "NoPropertyData". |
RMS-2234 |
Not possible to archive a measuring point. |
RMS-1178 |
MPT-number not available with an SMS. |
RMS-1117 |
Data from an unassigned gateway will not be taken (if encrypted). |
RMS-1093 |
Archiving crashed when copying measuring data. |
RMS-1051 |
Software exception: UpdateCalculations. |